Investigations
  • Holter monitoring b worn for as long as possible  c

Why?

  • Holter monitoring over 72 hours detects twice as many arrhythmias as 24 hours worth. c
  • It can help diagnose a cause in 27% of cases (95% CI: 21% to 33%) b

Holter monitoring detects more arrhythmias the longer it is worn

day c major arrhythmia detected 
(95% CI)
1 15% 
(8.3% to 23%)
2 11% 
(5.1% to 20%)
3 4.2% 
(0.8% to 12%)
 

Expiry date: July 2004
Levels of Evidence used in grading these guides

Author   CM   Ball
Reviewer   H   Oral
CAT Writers   CM   Ball , N   Shenker , CJ   Wotton