Clinical
features
Investigations
Therapy
Prevention
Prognosis
|  |  | | Investigations |
- event recorders
a

Why?
-
Event recorders produce more interpretable ECG tracings with symptoms and detect more clinically important arrhythmias than 48 hours of Holter monitoring
a
-
Event monitoring is cheaper
a
Event recorders detect more clinically important arrhythmias than Holter monitoring
| Patient |
Treatment |
Comparison |
Outcome |
CER |
RRR (95% CI) |
NNT
(95% CI) |
palpitations
a
|
event recorder for up to 3 months or until 2 events detected
|
Holter monitoring for 48 hours
|
interpretable ECG tracing
at
3
months
|
35%
|
93%
(36% to
100%)
|
3
(2 to
8)
|
|
|
|
|
clinically important arrhythmia detected
|
0%
|
|
5
(3 to
14)
|
|